  1. SIZE VALVE @ CHILLER MINIMUM FLOW (161 GPM FOR LAYOUT BASIS) AND AN APPROXIMATE PRESSURE DROP OF 15 PSI. BYPASS VALVE SHALL BE GLOBE VALVE OR CHARACTERIZED BALL VALVE. SET MINIMUM FLOW RATE AT 161 GPM IN ACCORDANCE WITH LAYOUT BASIS. VALVE ACTUATOR STROKE TIME SHALL BE 30 SECOND IN ACCORDANCE CHILLER MANUFACTURER.
  2. BROAD Intelligent Control System (ICS) realizes operator free for chiller and water distribution system. BROAD Global Internet Monitoring System actualizers fault prediction, analysis, trouble- shooting and energy-saving management by 24/7/365. BROAD offers free monitoring service to customers during chiller's whole lifespan.

Models Manuals; 1.5 HP DuraChill™ Chiller, Air-Cooled, Water-Cooled. 6800P, 6800T, 6900P, 6900T: En 2 -3 HP DuraChill™ Chiller, Air-Cooled, Water-Cooled.

ICS Chillers also offers a full range of industrial water cooled chiller packages. As with the air cooled chillers, each water cooled chiller is custom built to efficiently support your specific process cooling requirements. The industrial series water cooled chillers can accommodate a large range of process supply temperatures with the convenience of using existing cooled water systems and the flexibility of installation locations.

Ics water chiller manual defrost

Each packaged water cooled chiller includes all required components to allow for easy adaptation to your systems. This includes a large volume glycol reservoir, all required system pumps, and operational controls. Once the chiller is on site, the installation is limited to connection of the main power (distribution block or optional service disconnect), the process cooling loop (supply and return lines), and the condenser fluid lines.

Instructions

Please review the below specifications for general single unit system capabilities, however, we encourage you to contact us so that we can better understand your specific application and develop a custom packaged chiller to meet your needs. CONTACT

System Capacity

3 HP to 160 HP

Voltages

208 V to 600 V

Ics Water Chiller Manual Defrost

Reservoir

10 Gal to 1,000+ Gal

*Individual packaged chillers can be staged together for larger capacity requirements

Ics

Cooling Capacity

Ics Water Chiller Manual Instructions

20 MBH to 1,920 MBH (1 Ton to 160 Tons)

Ics Water Chiller Manual Troubleshooting

Frequencies

Ics Tae 051 Water Chiller Manual

50 or 60 Hz

Pump Capacities

Ics Water Chiller Manual Transmission

10 GPM to 1,000+ GPM

Product Type Operator's Manuals Supported Models
Refrigerated Recirculating Chillers 5000 Series
Refrigerated Recirculating Chillers
DuraChill Air- and Water-Cooled 1.5 HP Chillers
6800T
6900T
DuraChill™ Air- and Water-Cooled 2 and 3 HP Chillers
DCW300
DuraChill™ Air- and Water-Cooled Chillers 5, 7.5 and 10 HP
Liquid-to-Air Recirculator
3370TB
LM-Series & MM-Series Compact Chillers
LM-6M
MM-7M
LS-Series Compact Chiller
LS-5M
Model 4100 and 4200 Series Liquid-to-Liquid Coolers
Refrigerated Recirculating Chillers Operator's Manual - Multi-Language